Power Supplies
|
|
|
PA-4320AXR |
 |
|
|
|
Features
|
- Compact size for 4U Rackmount
- AC/DC 320W PS/2 Type 4U Hot Swap Redundant Power Supply with
ATX Output
- Input Voltage Range: Full Range (100~240VAC)
- Power System Fault Signal and Audible Alarm
- Output Voltage: 5V / 3.3V / 12V / -5V /-12V / 5VSB
- Safety Standard: CE, FCC, UL, CB, TUV
- EMI Standards:FCC Class A / VCCC Class 2.
- Aluminum case for excellent power dissipation
|
|
Specifications
|
| INPUT |
Voltage Rating |
Full Range (100~240VAC) |
| Input Current (115/230VAC) |
8A / 4A |
| Frequency |
47Hz~63Hz |
| In-rush Current |
40A/132VAC; 80A max./264VAC(at
cold start) |
| OUTPUT |
DC Voltage |
Ripple & Noise |
Total
Reg. |
Output Current Rating
MIN / MAX |
| 3.3V |
30mV |
±1% |
0A / 20A |
| +5V |
50mV |
±1% |
3.5A /35A |
| +12V |
120mV |
±1% |
1A / 16A |
| -5V |
100mV |
±2% |
0A / 0.5A |
| -12V |
240mV |
±2% |
0A / 0.5A |
| +5Vsb |
50mV |
±1% |
0A / 1.5A |
| +3.3V & +5V Power |
180W |
| Total Output Power |
304W |
| Hold up time |
20ms min. at 230V AC full load |
| Over Power
Protection |
105%~120% of max load |
| Over Voltage
Protection |
+5V: 6.25 VDC +/- 0.65 VDC
+3.3V: 4.10 VDC +/- 0.40 VDC
+12VDC:13.6 - 15.6 VDC |
| Efficiency |
70% min. at full load |
| Cooling |
Air convection by +12V DC
fan |
| Operation Temperature |
0 to 50 °C. Derate Linearly to 50% at 70
°C |
| Storage Temperature |
-20șC ~60șC |
| Humidity |
Operating: to 90% relative humidity, non-condensing
at 40ºC
Storage: to 95% relative humidity, non-condensing at 50ºC |
| MTBF |
100K hours at 25ºC ,70% full rated load
(calculated by MIL217E) |
| EMC |
a) FCC part 15, Subpart A, Class A computing
devices.
b) CISPR22 (EN55022) Class A.
c) VCCI Class 2. |
| Safety |
CE, FCC, UL, CB, TUV |
| Dimension |
175 (D)x 150 (W)x 86(H) mm |
|
|
|